Manuscript Water

3 – Physicist-Chemistry characteristics – physical Form: liquid – Density 25 C: 1,250 1,270g/cm3 (12% Al2O3) – Density 25 C: 1,280 1,320 g/cm3 (16 18% Al2O3) – pH the 10%:2,00 the 3,20 (12% Al2O3) – pH the 10%:3,50 the 4,00 (16 18% Al2O3) – Appearance: Lightly brownish yellow and – Exempt of persistent metals heavy and organic 4 – Dosage the dosage of the CAP is in function of the characteristic of the water to be treated 5 – Application the CAP can be applied pure or diluted on-line, in order to reach mixture and dispersion better. For application of the product, it will be able to use a dosadora diaphragm bomb. The polyethylene, PVC, polypropylene, PTFE material are adjusted for bombs in the feeding system. 6 – Manuscript the CAP will have to be handled as any acid product, to prevent its ingestion, contact with the skin and the eyes. If you have additional questions, you may want to visit Science education. In contact case, to wash the place reached with water per 15 minutes with a Sodium Bicarbonate solution 5% and to provide medical attendance.

7 – Packing Normally the CAP is supplied in bulk. But in specific cases they can be supplied in bombonas as request of the customer. MATERIALS AND METHODS Processes for application of the project Through some you analyze in laboratory was verified that the Policloreto of diluted aluminum 40% had a bigger efficiency in the treatment of the water. The used method was simply to catch 4 ml of pure solution and to dilute it in 20 ml of water. After made this if ml caught 1000 or 1 liter of effluent sample of rude and was adding policloreto of aluminum already diluted and other solutions as polymer and the hidrxido one of sodium (caustic soda water) and was verified that the effluent one was floculando better with the solution of the diluted CAP already. With this one evidenced that the diluted CAP was better of what pure. RESULTS AND QUARRELS After made the tests in laboratory had been made tests in the treatment station where this project was implanted. A container of 200 liters was caught and in it 40 liters of the pure CAP had been added and completed the container with 160 liters of water this in the part of the morning after 24 hours was verified that the water dealt with this diluted CAP had a better aspect the water was limpid and without loss of solids. In this effluent one treated with the diluted product they had been made you analyze of match and evidenced that the same it had been below of the previous day when still we used the pure product without being diluted. CONCLUSION After the accomplishment of the present work, concludes that: It had one significant reduction in the budget of the company in virtue of this product to be being diluted and not more used pure as old, therefore we used 4 bombonas of 260 liters p/ms and now alone we use 2 had a reduction of 50% in the budget of the company with this the money that sobrara of this economy can be used in other sectors of the treatment station.